| Operating Principle |
| |
 |
Differential
pressure P is created in the main
Flow by providing an Orifice plate in the main
pipeline. |
| |
 |
Because
of this P a branch of flow moves through
By-Pass line provided across
the orifice plate
from up stream side to down stream side of the
Orifice Plate. |
| |
 |
Additional
Range Orifice plate is provided in the By-Pass
line
which is designed such that flow through
range Orifice plate
flows in proportion with the
flow through main orifice plate. |
| |
 |
Hence
by measuring the flow from By Pass line we can
estimate the flow from Main Pipe line. |
|
| |
| Standard Features |
| |
 |
Easy to Maintain |
| |
 |
On - Line Installation |
| |
 |
Most Economical,Low
Cost |
| |
 |
Pipe Size - 40 NB
to 300 NB |
| |
 |
For High
Flow - 8M / Hr. To 1500M / Hr. |
| |
 |
Two tone powder coated
excellent finish |
| |
 |
No threads, No leakage,
Avoids corrossions |
| |
 |
Rangeability - 1:10 |
2 : 10 |
| |
 |
Heavy duty design with
maximum visibility |
| |
 |
Various options for
material of construction of wetted parts |
|
| |
|
| |
Main
Line
NB
MM |
PRESSURE
DROP METERS OF H2O |
1.2 |
2.5 |
3.8 |
5 |
10 |
1.2 |
2.5 |
3.8 |
5 |
10 |
|
LIQUID
M³ / Hr
|
|
AIR
NM³ / Hr |
40 |
8 |
12 |
14 |
16 |
22 |
|
246 |
350 |
425 |
492 |
730 |
50 |
13 |
19 |
22 |
27 |
38 |
|
407 |
577 |
713 |
815 |
1206 |
65 |
19 |
27 |
34 |
38 |
54 |
|
594 |
849 |
1019 |
115 |
1699 |
80 |
29 |
40 |
52 |
59 |
83 |
|
917 |
1274 |
1580 |
1835 |
2684 |
100 |
59 |
86 |
104 |
120 |
170 |
|
1869 |
2616 |
3228 |
3738 |
5437 |
125 |
95 |
136 |
163 |
188 |
272 |
|
2888 |
4078 |
5097 |
5777 |
8496 |
150 |
136 |
192 |
227 |
272 |
385 |
|
4248 |
5947 |
7306 |
8496 |
12234 |
200 |
227 |
340 |
408 |
476 |
658 |
|
7306 |
10365 |
12744 |
14613 |
21409 |
250 |
363 |
522 |
635 |
749 |
1044 |
|
11554 |
16482 |
20390 |
23109 |
33984 |
300 |
522 |
749 |
930 |
1066 |
1498 |
|
16482 |
23109 |
28036 |
32284 |
47577 |
|
|
| |
By
Pass Rotameter :- Just Insert Model.
As indicated in the name you have to just insert the entire
assembly in the pipe line between the two flanges. |

|
|
|
| |
By
Pass Rotameter :- Site Assemy Model.
This is an ecconimical model which consists of
1) Main
Orifice Plate
2) Glass Tube Rotameter
3) Range Orifice Plate |
 |
| ( PIPING, VALVE & ASSEMBLY - SCOPE
OF CLIENTS ) |
|
| |
| Technical Specification |
| Orifice Plate |
For main pipe designed for
standard Flanged. |
| Rotameters |
Glass Tube,
Roatameter Model T1, T2 |
| Range Orifice Plate |
Suitable to main Orfice Plate
in Ss316 |
| Accuaracy |
For Rotameter + 2% FS
For Complete Assembly of
By-Pass Rotameter + 4% of Flow |
|
|